Install the Iro Wall Mount to the wall using
the two screws included.
Reconnect the wires to the Wall Mount
terminals.
Required Wiring
Common Wires
Install into either white terminal slot. If you
have more than one common wire we
suggest entering one in each common slot
(left and right).
Zone Wires
Install in the green terminal slots.
Master/Pump Valve Wire (if present)
Install in the blue terminal slot, and enable in
Advanced Settings within the app.
Optional Hardware
Rain/Moisture Sensors (optional)
Install in the yellow terminal slots, and enable
in Advanced Settings within the app.
Hydraulic Indexing Valves
Indexing Valves are uncommon and typically
found in the state of Florida. Install following
the Master/Pump valve wiring instructions.
(above)
For details on Indexing Valves, reference
www.rachio.com/indexing